UL 1741-SA (Supplement A, published 2016) is the inverter listing supplement that tested compliance with California Rule 21 Phase 1 and 2 smart inverter functions. Superseded by UL 1741-SB (2020) for new installations in most US jurisdictions.
What UL 1741-SA Tested
UL 1741-SA added a specific test matrix to the base UL 1741 inverter listing, built around California’s Rule 21 rollout. Phase 1 functions covered anti-islanding detection and voltage/frequency ride-through — the inverter’s ability to stay connected through minor grid disturbances instead of tripping offline. Phase 2 functions added autonomous grid-support behavior: volt-VAR (adjusting reactive power output based on local voltage) and volt-Watt (curtailing active power output at high voltage). An inverter listed under UL 1741-SA had been lab-tested against both phases, which is what made it eligible for California interconnection at the time.
Why It Was Superseded
IEEE 1547 — the underlying technical standard both supplements test against — was revised to the 2018 edition, which introduced a third tier of requirements: utility-dispatched communications functions using the IEEE 2030.5 SunSpec protocol. UL 1741-SA’s test matrix stopped at Phase 2 and had no way to certify those communications capabilities, so UL published Supplement B in 2020 to close the gap. From that point forward, new interconnection applications in Rule 21 territory and most other high-DER states have required UL 1741-SB rather than SA. Systems that were already interconnected under UL 1741-SA are typically grandfathered and don’t need to be re-certified, but any new equipment installed today should carry the SB listing.
Related Reading
Because UL 1741-SA only comes up in practice on legacy California interconnections, it’s worth pairing this entry with UL 1741-SB to see exactly which test requirements changed between the two supplements. Anyone specifying equipment for a current project should also check the California AHJ solar permit guide, which covers how Title 24 and NEC 2020 (CEC) requirements interact with the utility’s own interconnection checklist. For teams comparing US inverter listing rules against international certification frameworks, qbitsenergy’s guide to solar inverter certification standards is a useful reference point outside the US market.
Frequently Asked Questions
5 commonly searched questions about UL 1741-SA.
What is UL 1741-SA?
Can I still install UL 1741-SA inverters?
Why was UL 1741-SA superseded?
How do I tell if an inverter is UL 1741-SA or UL 1741-SB listed?
Does Rule 21 still reference UL 1741-SA?
Need engineering-backed solar designs?
Heaven Designs delivers PE-stamped solar design packages, structural calculations, electrical engineering, and utility-compliant permit plans.
Nirav Dhanani